2021 2nd Alert LTI19 Floorman standing at air winch area fell from 8 meter height after removing floorplates and suffered pelvic fracture
On August 20th, 2021, at around 05:30 hours, the operational team removed the off-driller side (ODS) plate to connect the off drillers side MRC (mast raising cylinder) to lower the rig floor. Once the floorplate was removed, the air winch operator floorman stayed at the ODS air winch area, whereas his coworkers resumed other tasks. Suddenly the rig floor crew members (driller/ assistant driller and one Floor man) heard yelling from the substructure and realized that their coworker Air winch operator fell (fall distance 08.35 m height) and rested on the substructure area. The rig medic administered first aid to the Floor man before transporting him to Nimr PDO facility via MEDIVAC. The Floor man was conscious, oriented, and responding during his evaluation to Nimr clinic, then referred to Salalah hospital for further medical care. The floor man sustained head trauma (superficial wound), Pelvic fracture.
Ensure that step by step activity, risk, control and responsibilities are discussed with all involved personnel. Always ensure to intervene and apply the stop-work authority when deemed necessary. Always ensure to always supervise the task physically. Never leave the work site unattended Always ensure to maintain good housekeeping at the work area. Always stick with the plan otherwise inform your supervisor. Apply dynamic risk assessment review for any changes in the activity Always ensure to barricade immediately any opening/gaps or shifted handrails