2021 2nd Alert LTI23 Drill pipe fell from the tilted out rigger of the catwalk pipe rack, rolled over and hit the NTPs' left leg
On October, 16 at around 23:51 Hrs after completing 7” liner job, 2 singles and 7 stands of 5” drill pipe were laid down on to the catwalk pipe racks. While forklift was trying to remove the two 5” singles of drill pipe they fell from the tilted-out riggers of the catwalk pipe rack. The NTP came to stop the forklift and assess the next operation During this intervention the loader reversed unit away from piperacks. One Drill pipe rolled across second dill pipe hitting the IP on his left leg. Why it happened/Finding : Poor planning on removing Singles of Drill Pipe Pipe racks were in laydown mode contributed to make the task difficult. Could have stopped the job and elevated the racks to horizontal and removed the two singles SWA was partially enacted - Line of fire was not identified and poorly recognized No JSA /TBT were not held prior removing the two singles.
Ensure all the crew members respect the No Go zone management available at location. Ensure review of POOH JSA while laying tubulars adding: Recovery of tubular if miss handled (falls from racks) Line of fire in the above event Ensure when the task changes apply SWA , assess the risk associated to the task. Ensure proper Job Planning is key to a successful for safe operation