Sign In
2023 Second Alert LTI#01 Burning from Sulphur
While a Field Operator and his Supervisor were inside the boundary of the Sulphur blocking area, the Operator used his right foot to remove a build-up of Sulphur. At the same time, he was positioned on a thin crust of solid Sulphur which was covering liquid Sulphur at a temperature of 135c. The weight of the Operator fractured the crust and exposed his feet to the hot liquid underneath, resulting in 2nd degree burns to both feet. He was initially treated at PDO Yibal Clinic before being referred to Nizwa Hospital for further treatment.
Always follow the specific requirements of the procedure for your safe work (e.g. SOP, Method Statement, JSA). Always wear the correct PPE required for specialist activities. If you don’t know what it is…..find out! Always report equipment that is faulty or needs repairing – it could cause an incident. Always contact PDO Emergency number (5555) – When an incident happened. Procedures have specific requirements within them – follow them to keep safe!
IP entered the area 1 hour after Sulphur pouring – the procedure highlights no one should enter area for a period of 24 hrs. The correct specialist PPE was not worn as the operator and supervisor underestimated the risk of liquid Sulphur. The Sulphur pouring arm had an oil leak which temporarily stopped the pouring process and allowed Sulphur to build up which required operator intervention.

Category:Second AlertsDocument Type:Safety
Format:Viewers:13
Download: